11.8.2

Instruction Set in MODBUS-RTU Protocol
With the MODBUS-protocol the data are read and written via
register accesses. The following register accesses are defined
for the communication with the sensor modules:

Function number

Function

03 hex

Read Holding Register (Read/Write-Register)

04 hex

Read Input Register (Read-Only-Register)

06 hex

Pre-set Single Register

08 hex

Diagnostic

10 hex

Pre-set Multiple Register

Table 11.15 MODBUS commands

Read Holding Register

Description:
By this command input/output registers (read/write registers)
can be read.

request telegram

ADR

FNR

REGSTA

REGNUM

CRC

03

MSB

LSB

MSB

LSB

MSB LSB

response telegram

ADR

FNR

BYTNUM

D0 D1

03

Dn CRC

MSB LSB

ADR ............ module address (hex 00..7F)
FNR ............ function number (hex 03)
REGSTA ..... address of the first register to be read
REGNUM .... number of registers to be read

Hardware Manual COMBILOG 1022