Format of the status message:
=
Time ; N ; Location ;
SN ; A ; KS ; MS
=
Start-Delimiter
Time Date/Time (12 character, format YYMMDDHHmmSS)
;
delimiter
N
Module address (2 char)
Location
Module location (20 char)
SN
Serial number (6 char)
A
Alarm
condition
(2
char)
01
at
system
error
02
at
range
error
03 at threshold condition
CS
channel status (8 char, see chapter 11.8 )
MS module state (4 char, see chapter 11.8)
Example:
=000121083120;01;Testboard ;
090658;03;00000000;0000
In case of using a GSM modem it is possible to send mes-
sages as SMS (short message service). In the configuration
program the user has to define the number of the service
centre (depending on the net provider), the destination number
and the message itself. For every dial condition described
above, including the 4 possible alarm conditions, a message
can be defined separately. This message will be transmitted to-
gether with the device type (COMBILOG), the serial number
and the location of the module.
To get a list of supported GSM modems please contact your
local distributor or Theodor Friedrichs & Co. directly.
Hardware Manual COMBILOG 1022
143