7 profibus protocol, 1 telegram format for the profibus protocol – Kipp&Zonen COMBILOG Data Logger User Manual
Page 117
11.7
PROFIBUS protocol
11.7.1
Telegram Format for the Profibus Protocol
For data transmission via PROFIBUS following telegram
formats are relevant for the data logger COMBILOG 1020:
Formats with fixed information section length without data
field:
S D 1
F C S
D A S A F C
E D
Formats with variable information section length with data
field:
SD2
LE
DataUnit
FCS
LEr
DA
SA
FC
ED
SD2
Formats with fixed information section length with data field:
SD3
DataUnit
FCS
DA
SA
FC
ED
With PROFIBUS the various telegram formats are differenti-
ated by varying Start-Delimiters (SD). They can also be called
SD1-, SD2- or SD3-telegrams in this context. The telegram
formats are valid both for request and response telegrams.
However, a request telegram does not necessarily have to be
followed by a response telegram of the same format. In addi-
tion to that there is a telegram which consists of one character
only and which is used as either positive or negative acknow-
ledgement, according to the kind of request.
Short acknowledgement:
S C
Hardware Manual COMBILOG 1022
117