3 installation, 1 mounting / fixing, 2 protective system – Kipp&Zonen COMBILOG Data Logger User Manual
Page 19: Installation
3
INSTALLATION
3.1
Mounting / Fixing
The data logger COMBILOG 1022 has a snap-on mounting for
installation on standard profile rails 35 mm (1.4 inch) according
to DIN EN 50022.
Installation on the DIN rail is performed by means of the four
straps on the rear side of the data logger. First push the two
straps on the bottom behind the notch of the DIN rail and then
press the data logger on the DIN rail until the two straps on the
top snap in.
In order to take the data logger off the DIN rail slide the module
lateral off the rail or in case it is not possible lift the data logger
slightly so that the straps on the top get off the notch and the
data logger can be taken off easily by pulling.
Attention: Refer to protection earth hints in chapter 3.5!
3.2
Protective System
The data logger has an IP20 protective system. For outdoor in-
stallations data logger COMBILOG 1022 can be installed in a
stainless housing type 9920, thus featuring IP66 standard.
Hardware Manual COMBILOG 1022
19