beautypg.com

Kipp&Zonen COMBILOG Data Logger User Manual

Page 167

background image

Resistance measurement

range

accuracy

(1)(3)

Resolution /

noise

(1)

linearity

(2)

temperat.

drift

(2)

20 k

10

10 k

5

5 k

2.5

0.003 %

2.5 k

1.25

0.05 %

1.25 k

0.63

0.01 %

25 ppm/K

625

0.31

312.5

0.15

0.010 %

5 ppm/K

(4)

200

0.1

0.003 %

(1)

values for T=20 °C , (2) values estimated from the
hardware specification

(3)

values correspond to 80 % of the measuring range

(4)

with external drift compensation, reference resistance
with TCR 1

Achievable absolute accuracy with voltage measuring incl. drift correction:

typical

±

3 µV

Achievable accuracy for temperature measurement with Pt 100 resistance

(measuring range -200°...850 °C, temperature range -200°...200 °C, scan

rate 1 s, averaging interval 1 min)

without drift correction:

0.1 °C with ambient temperatures

0 °C...+40 °C

with external drift correction:

typical 0.05°C with ambient temperat-

ures

-40 °C...+85 °C

Reference resistance 100

, TCR 1

Hardware Manual COMBILOG 1022

167