Reznor SHH (Indoor PreevA) Unit Installation Manual User Manual
Page 6
Form I-PDH/SDH/PEH/SHH/PXH, Page 6
Option
Shipped Loose with the Heater and Shipped Separate
Components
AG3, AG60 On/Off Control Switch, P/N 39732; Discharge Air Sensor Holder,
P/N 115850; Discharge Air Sensor Holder Bracket, P/N 213612
AG15, AG61
On/Off Control Switch,
P/N 39732; Remote Ductstat Temperature
Selector,
P/N 115848; Stage Adder Module(s), P/N 115849;
Discharge Air Sensor Holder,
P/N 115850; Discharge Air Sensor
Holder Bracket,
P/N 213612
AG16, AG62
On/Off Control Switch,
P/N 39732; Remote Temperature Selector,
P/N 115848; Stage Adder Module(s), P/N 115849; Digital
Temperature Display,
P/N 115852; Discharge Air Sensor Holder,
P/N 115850; Discharge Air Sensor Holder Bracket, P/N 213612
DG1, DG2
Room Command Module,
P/N 211423
DG5, DG6
Room Command Module,
P/N 211424; Discharge Air Sensor
Holder,
P/N 115850; Discharge Air Sensor Holder Bracket, P/N
213612
D12B, D12C,
D12D, D12E,
D12F, D12G
Discharge Air Sensor Holder,
P/N 115850; Discharge Air Sensor
Holder Bracket,
P/N 213612)
GE10
Potentiometer,
P/N 16110
GE15
Pressure Null Switch,
P/N 88052
GE21
Enthalpy Sensor and Parts to install,
P/N 220686
GE22
Two Enthalpy Sensors and Parts to install, (2)
P/N 220686
AU7L, AU7R
Duct Humidity/Temperature Sensor,
P/N 206081; Mounting Bracket,
P/N 207499 (NOTE: These parts will be factory installed if the
system includes a mixing box, Option MXB1.)
TABLE 1A - Shipped-Separate or Shipped-Loose Components of
Factory-Installed Options
Models SDH and SHH - Shipped-Separate Combustion Air Inlet/Vent
Terminal Kit
A vent/combustion air terminal kit (Option CC2 or CC6) is
required for all Model SDH
and Model SHH installations. Be sure that the correct venting/combustion air terminal
kit is at the installation site. Optional kits are unique for each Model; compare P/N’s
with
TABLE 1B.
TABLE 1B - Combustion Air Inlet/Vent Terminal Kits
Model
Option
Sizes
Kit P/N
SDH
CC6
75-125
211762
150-400A
211763
CC2
75-125
205895
150-400A
205896
SHH
CC6
All
221247
CC2
All
221248
NOTE: Instructions
for installing the vent/
combustion air kit are in the
vent manual, either Form
I-SHH-V or Form I-SDH-V in
the literature bag.
Shipped-Separate or Shipped-Loose Items
Some control options have parts either shipped loose with the heater, shipped sepa-
rately, or mounted on a shipped-separate remote console (if ordered). If your unit is
equipped with any of the control or air inlet options in
TABLE 1A, be sure these parts
are available at the job site. NOTE: Other optional field-installed controls or sensors
may also be required for some control options.
3.0 Receiving,
Moving,
Uncrating, and
Preparing for
Installation
(cont’d)