0 mechanical (cont’d), 2 cooling coil module dimensions, Cd e f a – Reznor SHH (Indoor PreevA) Unit Installation Manual User Manual
Page 34: Table 20a - dx cooling coil module dimensions

Form I-PDH/SDH/PEH/SHH/PXH, Page 34
C
D
E
F
A
ø 3/8 Hot Gas Bypass
ø 7/8 Liquid Lines
ø 1-3/8
Suction
Lines
1
MPT
Drain
2-13/32
(61mm)
10-5/8(270mm)
12-1/2(318mm)
12-13/16
(325mm)
24-13/16(630mm)
10-1/8
(257mm)
7-7/8(200mm)
2-1/8(54mm)
B
3/4 (19mm) duct flange
1-5/32
(29mm)
3/4 (19mm)
duct flange
18-3/8
(467mm)
Inlet Air
View
(with duct
flange*)
Side
View
NOTE: See
Paragraph 5.1,
page 10, for
weights.
FIGURE 27A - DX Cooling Coil Module Dimensions (without reheat)
*If there is a mixing box or evap cooler attached, the coil cabinet will not have a duct flange.
TABLE 20A - DX Cooling Coil Module Dimensions
Model PDH
or SDH
Model PEH
Model
SHH
Model
PXH
A
B
C
D
E
F
A
B
C
D
E
F
Dimensions (inches)
Dimensions (mm)
75/100
10A/20A/40A
N/A
000A 27-3/4 22-7/8 11-1/8 30-1/4 25-9/32 17-9/32 705 581 283 768 642 439
125/50
15B/30B/60B
N/A
000B 27-3/4 26-1/2 11-1/8 30-1/4 25-9/32 17-9/32 705 673 283 768 642 439
175/200/225 N/A
130/180 000C 27-3/4 22-7/8 11-1/8 30-1/4 25-9/32 17-9/32 705 581 283 768 642 439
250/300
30D/60D/90D/120D 260
000D 27-3/4 34-3/4 15-7/32
35
29-29/32 21-29/32 705 883 387 889 760 556
350/400A
40E/80E/120E
350
000E
27-3/4 45-3/4 15-7/32
35
29-29/32 21-29/32 705 1162 387 889 760 556
34-1/16 (865)
37-1/16 (941)
42-5/8 (1083)
52-5/16 (1329)
55-5/16 (1405)
Suction Lines
1” MPT
Drain
Fitting
2-1/2 (64)
Hot Gas Bypass
Grommets (Cross
slit at installation.)
Liquid Line
Grommets (Cross
slit at installation.)
Coil Access
Filter and
Compressor
Access
52-15/16 (1345)
A
1-3/32
(28)
6-1/8
(156)
B
C
4-5/8
(117)
D
H
G
F
E
Side View
Inlet Air
View*
Airflow
Model PDH
or SDH
Model
SHH
Model PEH
Model
PXH
A
B
C
D
E
F
G
H
A
B
C
D
E F
G
H
Dimensions (inches)
Dimensions (mm)
75/100
N/A
10A/20A/40A
000A 33-3/4 33-13/16 24-23/32 34-17/32 13-3/8 19-5/8 23-7/8 30-1/8 857 859 628 877 340 498 606 765
125/150
N/A
15B/30B/60B
000B 43-3/4 43-13/16 34-23/32 34-17/32 13-3/8 19-5/8 23-7/8 30-1/8 1111 1113 882 877 340 498 606 765
175/200/225
130/180
N/A
000C 33-3/4 33-13/16 24-23/32 43-7/8 15-3/8 21-5/8 27-7/8 34-1/8 857 859 628 1114 391 549 708 867
250/300
260
30D/60D/90D/120D 000D
50
50-5/32 40-15/16 43-7/8 15-3/8 21-5/8 27-7/8 34-1/8 1270 1274 1040 1114 391 549 708 867
350/400A
350
40E/80E/120E
000E
58
58-5/32 48-15/16 43-7/8 15-3/8 21-5/8 27-7/8 34-1/8 1473 1503 1243 1114 391 549 708 867
FIGURE 27B -
DX Cooling
Coil Module
Dimensions
with Reheat
Circuit
*If there is no
mixing box or evap
cooler attached,
the inlet air opening
would have an
optional duct
flange as shown in
FIGURE 27A.
TABLE 20B - Dimensions of DX Cooling
Coil Module with Reheat Circuit
6.6.2 Cooling Coil Module Dimensions
6.0 Mechanical
(cont’d)
6.6 Cooling Module - Option AU on PDH, SDH, PEH, SHH,
and PXH (cont’d)