Page 10: 0 suspension and mounting, 1 weights, 2 lifting and suspension, Figure 3 - corner weight locations

background image

Form I-PDH/SDH/PEH/SHH/PXH, Page 10

5.0 Suspension

and Mounting

TABLE 5 - Weights

(lbs and kg) of Basic

System and Factory-

Installed Optional

Modules

5.1 Weights

Before installing, check the support structure to be sure that it has sufficient load-bear-

ing capacity to support the weight of unit during installation and operation. Suspension

or mounting is the responsibility of the installer.

TABLE 6 - Corner

Weights of Heat Module

and Blower Section

only for Models Listed

control side

Important NOTES: If controls are on the right side, switch left and right side weights.

Weights do not include the blower motor or any optional modules.

FIGURE 3 - Corner

Weight Locations

Model PDH and Model SDH (gas-fired heat)

75

100

125

150

175 200 225

250

300

350

400A

Model PEH (electric heat)

10A, 20A, 40A 15B, 30B, 60B

N/A

30D, 60D, 90D, 120D

40E, 80E, 120E

Model SHH (high efficiency gas-fired heat)

N/A

130 180

---

260

--

350

--

Model PXH (no heat)

000A

000B

000C

000D

000E

Approximate Net Weights - lbs (does not include motor weight)

Basic Gas Heat & Blower Section (PDH or SDH)

323

331

413

421

478 492 492

615

629

721

732

Basic Electric Heat & Blower Section (PEH)

296

368

N/A

523

594

Basic High Efficiency Gas Heat & Blwr Sctn (SHH)

N/A

538 544

--

729

--

889

--

Blower Section (PXH)

245

307

333

431

483

Approximate Weights (lbs) of factory-attached options (add to weight listed above)
Option AR8, on/off damper (no mixing box)

34

45

56

73

85

Option MXB1

Mixing Box Module

w/o Dampers

2 inlets, single wall

119

132

134

159

174

2 inlets, double wall

146

165

166

199

216

1 inlet, single wall

115

127

130

154

169

1 inlet, double wall

146

166

166

201

219

Cooling Coil

Module with

heaviest coil

weight*

DX coil without

reheat pump

4 row coil

214

252

256

329

365

6 row coil

235

280

284

373

418

DX coil with

reheat pump

4 row coil

331

382

394

494

547

6 row coil

352

410

422

538

600

Chilled water

(filled)

4 row coil

301

363

373

497

559

6 row coil

351

431

441

604

686

Evaporative

Cooling Module

with dry media

12" media

120

141

136

172

190

with wet media &

3" of water

12" media

262

263

218

279

272

Hot Water Heat Module - for PXH with

HW2 only (does not include water wt)

w/4 row,

14 fpi coil

145

175

177

236

263

Approximate Net Weights - kg (does not include motor weight)

Basic Gas Heat & Blower Section (PDH or SDH)

147

150

187

191

217

223

223

279

285

327

332

Basic Electric Heat & Blower Section (PEH)

134

167

N/A

237

269

Basic High Efficiency Gas Heat & Blwr Sctn (SHH)

N/A

244

247

--

331

--

403

--

Blower Section (PXH)

111

139

151

195

219

Approximate Weights (kg) of factory-attached options (add to weight listed above)

Option AR8, on/off damper (no mixing box)

15

20

25

33

39

Option MXB1 Mixing

Box Module w/o

Dampers

2 inlets, single wall

54

60

61

72

79

2 inlets, double wall

66

75

75

90

95

1 inlet, single wall

52

58

59

70

77

1 inlet, double wall

66

75

75

91

99

Cooling Coil Module

with heaviest coil

weight*

DX coil without

reheat pump

4 row coil

97

114

116

149

166

6 row coil

107

127

129

169

190

DX coil with reheat

pump

4 row coil

150

173

179

224

248

6 row coil

160

186

191

244

272

Chilled water (filled)

4 row coil

137

165

169

225

254

6 row coil

159

195

200

274

311

Evaporative Cooling

Module

with dry media

12" media

54

64

62

78

86

with wet media &

76mm of water

12" media

119

119

99

127

123

Hot Water Heat Module - for PXH with

HW2 only (does not include water weight)

w/4 row,

14 fpi coil

66

79

80

107

119

* Cooling coil cabinet

module weight is

estimated for heaviest

coil. If more accurate

information is needed,

check with your

distributor or Reznor

®

Representative who

either has the specific

information in the order

specifications or has

software to generate the

information.

5.2 Lifting and

Suspension

The heavy gauge base of the unit has forklift openings in both sides. See

FIGURE

4. Use these openings to move and lift the unit. (NOTE: If system has more than two

optional modules, check for labels identifying which side to lift.) Braces underneath are

spaced to accommodate a minimum fork length of 24” (610mm).

In addition, the base of all units has a lifting hole at each corner. Systems with a mixing

box and/or a cooling cabinet have additional side suspension points. When lifting, lift

from all of the suspension points on the unit (4, 6, or 8). Use spreader bars to lift the

unit straight up with vertical force only.

Top View

SHH

130

180

260

350

Corner

(FIG 3)

Approx Wt (lbs) - Heat

Section & Blower only

LR

81

82

127

188

RR

87

88

144

192

RF

193

193

241

264

LF

180

180

217

245

Corner

(FIG 3)

Approx Wt (kg) - Heat

Section & Blower only

LR

37

37

58

85

RR

39

40

65

87

RF

88

88

109

120

LF

82

82

98

120

PEH

10A, 20A, 40A

15B, 30B, 60B

30D, 60D, 90D, 120D

40E, 80E, 120E

Approx Wt of

Each Corner

lbs

kg

lbs

kg

lbs

kg

lbs

kg

74

34

92

42

131

59

149

68

PDH/SDH

75

100 125 150 175 200 225 250 300 350 400A

Corner (FIGURE 3) Approximate Corner Weights (lbs) - Heat Section & Blower only

LR

70

70

92

92

80

80

80

124 124 158

158

RR

63

63

87

87

74

74

74

110 110 155

155

RF

92

96

113 117 156 163 163 180 187 198

202

LF

98

102 121 125 168 175 175 201 208 210

217

Corner (FIGURE 3) Approximate Corner Weights (kg) - Heat Section & Blower only

LR

32

32

42

42

36

36

36

56

56

72

72

RR

29

29

39

39

34

34

34

50

50

70

70

RF

42

44

51

53

71

74

74

82

85

90

92

LF

44

46

55

57

76

79

79

91

94

95

98