Interlogix NS3702-24P-4S User Manual User Manual
Page 365
365
The Page includes the following fields:
General Settings
Object
Description
Enable Loop
Protection
Controls whether loop protections is enabled (as a whole).
Transmission Time
The interval between each loop protection PDU sent on each port. valid values
are 1 to 10 seconds.
Shutdown Time
The period (in seconds) for which a port will be kept disabled in the event of a
loop is detected (and the port action shuts down the port). Valid values are 0 to
604800 seconds (7 days). A value of zero will keep a port disabled (until next
device restart).
Port Configuration
Object
Description
Port
The switch port number of the port.
Enable
Controls whether loop protection is enabled on this switch port.
Action
Configures the action performed when a loop is detected on a port. Valid values
are Shutdown Port, Shutdown Port and Log or Log Only.
Tx Mode
Controls whether the port is actively generating loop protection PDU's, or
whether it is just passively looking for looped PDU's.
Buttons
: Click to apply changes
:
Click to undo any changes made locally and revert to previously saved values.