beautypg.com

Interlogix NS3702-24P-4S User Manual User Manual

Page 362

background image

362

Reboot & Alarm:

It means system will reset the PoE port and issue an

alarm message via Syslog, SMTP.

Alarm:

It means system will issue an alarm message via Syslog, SMTP.

Reboot Time (30~180s)

This column allows user to set the PoE device rebooting time, due to there are so

many kind of PoE device on the market and theyhave different rebooting time. The

PD Alive-check is not a defining standard, so the PoE device on the market doesn’t

report reboots done information to NS3702 PoE Switch, so user has to make sure

how long the PD will be finished to boot, and then set the time value to this column.

System is going to check the PD again according to the reboot time. If ou can not

make sure precisely booting time, we suggest you to set it longer.

Buttons

: Click to apply changes

: Click it to reset configuration which has not been saved yet.