4 port sequential – Interlogix NS3702-24P-4S User Manual User Manual

Page 351

background image

351

A PD will return to Class 0 to 4 in accordance with the maximum power draw as specified by

Table 4-16-1.

Class

Usage

Range of maximum power used by the PD

Class Description

0

Default

12.95 watts (or to 15.4 watts for AF mode)

25.5 watts (or to 30.8 watts for AT mode)

Mid power or High power

1

Optional

0.44 to 3.84 watts

Very low power

2

Optional

3.84 to 6.49 watts

Low power

3

Optional

6.49 to 12.95 watts (or to 15.4 watts)

Mid power

4

Optional

12.95 to 25.50 watts (or to 30.8 watts)

High power

Table 4-16-1 Device Class

4.16.4 Port Sequential

This page allows the user to configure the PoE Ports started up interval time

. The PoE Port will start up one by one as

Figure 4-16-3

shows.

Figure 4-16-3:

PoE Port Sequential Power Up Interval Configuration Screenshot

The PoE port will start up after the whole system program has finished running.

The page includes the following fields:

Object

Description

Sequential Power up

Option

Allows user to enable or disable Sequential Power up function.

Sequential Power up

Interval

Allows user to configure the PoE Port Start Up interval time.

Sequential Power up

Port Option

There are two modes for Starting Up the PoE Port

By Port:

The PoE Port will start up by following Port number.

By Priority:

The PoE Port will start up by following the PoE Priority.