beautypg.com

ClearOne comm CONVERGE SR 1212 User Manual

Page 97

background image

92

use the AGC/ALC radio buttons to select Off, ALC, or AGC. the default is off. alC is performed automatically;
there are no user-configurable settings for alC.

NOTE: agC occurs after gain and filter settings in the audio signal path.

the configuration controls for agC are described in the following sections.

maximum Gain Slider

set the Target Level first, then set the maximum Gain that you want the agC to apply to the signal. maximum
gain is set using an rms (root mean square) level, which is the average magnitude of the audio signal over time.
maximum gain range is 0 to 18dB in 1dB steps. the default value is 6dB.

Target Level Slider

Target Level (rms) sets dB level for agC to maintain. target level range is from -30 to 20dB in 1dB steps. the
default target level is 0dB.

Active Gain meter

the Active Gain meter displays the gain adjustment being applied to the channel by agC.

Response Time Slider

Response Time sets the amount of time (in milliseconds) over which the level is averaged before agC is activated
or deactivated.

Threshold Slider

Threshold sets the dB level at which agC engages. the threshold is set using an rms (root mean square) level,
which is the average magnitude of the audio signal over time.

NOTE: setting the threshold above the background noise level will prevent agC from amplifying

background noise.