ClearOne comm CONVERGE SR 1212 User Manual
Page 268
263
PRGSTRING – Program String
this command sets/reports a programmed string.
COMMAND FORM
: DEVICE PRGSTRING
Argument Type
Size
Values
units
ID
unsigned Integer
4
0 – 7
value
string
80
Clear = Clear current value
1 – 80 Chars
(null to query in text)
special Characters:
\a = alert
\b = backspace
\f = form feed
\n = new line
\r = carriage return
\t = horizontal tab
\v = vertical tab
\\ = backslash
PTTTHRESHOLd – Push to Talk Threshold
this command selects/reports the setting of the push to talk threshold for a microphone.
Command Form
: DEVICE PTTTHRESHOLd
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
3 (m)
value
Float
2
-100 to 0
(null to query in text)
dB
PuSHTOTALk – Push to Talk
this command selects/reports the setting of push-to-talk for a microphone.
Command Form
: DEVICE PuSHTOTALk
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
3 (m)
value
unsigned Integer
2
0 = off
1 = on
2 = toggle
(null to query in text)
RAmP – Ramp Gain Adjustment
this command starts / stops the gain ramp for an input, output or assignable processing block. There is no
query associated with this command.
Command Form
: DEVICE RAmP
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
1, 2, 3, 5, 7, 12, 16, 17 (I, J, o, m, p, l, F, t, r)
rate
signed Integer
1
-50 – 50
If value=0, the ramp will stop.
If value< 0, the gain will ramp down.
If value>0, the gain will ramp up.
dB / s
target
signed Integer
1
-65 – 20
If null in text or 0x80 in binary, the ramp will use
the channel’s maximum and minimum for a target.
dB