SIGGENSwEEP – Signal Generator Sweep

this command starts the signal generator with a tone and does a sweep. If Repeat is 0, the signal generator will
turn off after the sweep. If Repeat is 1, the signal generator will turn off after signal generator timeout. to stop
the sweep, send a sIggenen command with a 0. During the sweep, the box will send out updated sIggen
commands.

Command Form

:

DEVICE SIGGENSwEEP

Argument

Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

1, 3, 7 (I, m, l)

amplitude

signed Float

2

-60.00 – 20.00

dB

start
Frequency

unsigned Float

4

20.00 – 20000.00

hz

end
Frequency

unsigned Float

4

20.00 – 20000.00 (must be greater than the
start)

hz

Increment
Frequency

unsigned Float

4

1.00 – 20000.00

hz

rate

unsigned Integer

2

10 – 2000 ms

hz

repeat

unsigned Integer

2

0 = repeat off
1 = repeat on

SIGTOuT – Signal Generator Time Out

sets the signal generator time out for the unit.

Command Form

: DEVICE SIGTOuT [value]

Argument Type

Size

Values

units

value

unsigned Integer

4

0 = Disable
1 – 30
(null to query in text)

min

SLVL – Speech Level Control

this command selects/reports the setting of speech level Control.

Command Form

: DEVICE SLVL [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

3 (m)

value

unsigned Integer

2

0 = off
1 = on
2 = toggle
(null to query in text)

SmTPSRV – SMTP Mail Server Address

this command selects/reports the Ip address of the smtp mail server, and the email address the unit’s smtp
client sends messages to.

Command Form

: DEVICE SmTPSRV [value address]

Argument

Type

Size

Values

units

value

Ip address

4

(null to query in text)
(0.0.0.0 Clears Ip and string)

address

string

40

1 – 40 characters
(null to query in text)