ClearOne comm CONVERGE SR 1212 User Manual
Page 115
110
Telco Settings Tab
settings available on the Telco Settings Tab include:
Auto Answer: set the number of rings before the unit connects an incoming call (or disable the function). the
default is Disabled.
Auto-disconnect: select the auto disconnect mode to control when the unit disconnects a connected call. modes
include Loop drop + Call Progress, Call Progress, and Loop drop, and Off. the default is loop Drop + Call
progress.
Ring Type: select from three different ring tones (Type 1, Type 2, Type 3). to test a particular tone, click Test after
you have selected the tone.
Telco Adaptation: some applications require the unit to adapt to line conditions using a white-noise burst (Noise)
rather than automatically (auto). the default is Auto.
Hook Flash: sends a momentary interruption in the line seizure, allowing activation of options such as 3-way
calling, call waiting, and call hold. this feature is dependent on the services offered by your telephone company.
you can set the duration of the hook flash using the slider or the selector box. range is 50ms to 2 seconds in 10ms
steps. the default is 250ms.
dTmF Level: this feature allows you to adjust the DtmF tone level in relationship to the participant audio level
in the room. the level can be adjusted in 1dB steps from a nominal level of 0dB to plus or minus 12dB in 1dB
increments. the default is 0dB.
Audible Ring Indication: When this feature is enabled, an audible ring is heard for incoming calls. the level
adjustment allows you to customize the level in relationship to the participant audio level in the room. the level can
be adjusted in 1dB steps from a nominal level 0 (default) to plus or minus 12dB in 1dB increments. the default is
0dB.
Audible Hook Indication: When the unit goes off hook (connects) a beep is injected into the receive channel and
transmit channel of the unit. When the unit goes on hook (disconnects), a series of two beeps is injected into the
receive channel to indicate that the call has been dropped. this indicator can be turned on or off using the Audible
Hook Indication check box. the default is on. the level adjustment allows you to customize the level in
relationship to the participant audio level in the room. the level can be adjusted using the slider or selector box from
nominal level 0 to plus or minus 12dB in 1dB steps. the default is 0dB.
Ringer Cadence:
standard: uses the cadence specified in the Country Code to detect the standard ring cadence per country.
•