ClearOne comm CONVERGE SR 1212 User Manual
Page 255
250
mAx – Maximum Gain Setting
this command changes or reports back the maximum gain setting for an input, output or assignable processing
block.
Command Form
: DEVICE mAx
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
1, 2, 3, 5, 7, 12, 16, 17 (I, o, m, p, l, F, t, r)
value
signed Float
2
-65.00 – 20.00
(null to query in text)
dB
mC – Multi-Channel Mode
this command groups audio controls for channels. audio Controls include gain, ramp gain, and mute.
Command Form
: DEVICE mC
Argument
Type
Size
Values
Channel
Channel
1
1 – n (max number of channels in multi-Channel group divided by 2)
group
group
1
128 (no text group)
multi-
Channel
group
group
2
only 23 (J) accepted for now.
see groupandChannels
Bitmap
hexadecimal
Integer
4
mCGAIN – Multi-Channel Gain
this command that groups adjusts/reports audio gain of the grouped channels.
Command Form
: DEVICE mCGAIN
Argument Type
Size
Values
units
Channel
Channel
1
1 – n (max number of channels in multi-Channel
group divided by 2)
group
group
1
128 (no text group)
multi-
Channel
group
unsigned
Integer
2
only 23 (J) accepted for now.
see groupandChannels
value
string
4
-99.90 – 99.90
(null to query in text)
dB
absol./
rel.
0
a = absolute
r = relative
null = relative