beautypg.com

ClearOne comm CONVERGE SR 1212 User Manual

Page 261

background image

256

reserved

2

0

OFFA – Off Attenuation Mode

this command selects/reports the off attenuation value of a mic channel.

Command Form

: DEVICE OFFA [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

3 (m)

value

unsigned
Float

2

0.00 – 60.00
(null to query in text)

PAA – PA Adaptive Mode

this command selects/reports pa adaptive mode for the specified mic.

Command Form

: DEVICE PAA [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

3 (m)

value

unsigned Integer

2

0 = off
1 = on
2 = toggle
(null to query in text)

PACEN – PA Softclipper Enable

this command changes enables the softclipper function on a power amplifier channel.

Command Form

: DEVICE PACEN [value]

Argument Type

Size

Values

units

Channel

Channel

1

see groups and Channels

group

group

1

23 (J)

value

unsigned
short

2

0 = off
1 = on
2 = toggle
(null to query in text)

PAENERGy – PA Energy-saver mode

this command switches the 36-volt rails off and on for the power amplifier. It is intended to be used for a low power
or energy saving mode.

Command Form

: DEVICE PAENERGy [value]

Argument Type

Size

Values

units

Channel

Channel

1

see groups and Channels

group

group

1

23 (J)

value

unsigned
short

2

0 = energy saver mode oFF (power amp on)
1 = energy saver mode on (power amp off)
(null to query in text)