dEVICESuBTyPE – Sets the Subtype of a Connected Device

this command enables/disables or reports the current type of device connected to an input or output.

Command Form

: DEVICE dEVICESuBTyPE [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

1, 2, 3, 7 (I, o, m, l)

value

unsigned Integer

2

(null to query in text)

dEVICETyPE – Sets the Type of a Connected Device

this command enables / disables or reports the current type of device connected to an input or output.

Command Form

: DEVICE dEVICETyPE [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

1, 2, 3, 7 (I, o, m, l)

value

unsigned Integer

2

(null to query in text)

dFLTm – Default Meter

this command selects/reports the setting of the default meter on the front panel.

Command Form

: DEVICE dFLTm [Channel group position]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels
(null to query in text)

group

group

1

1, 2, 3, 7, 16, 17 (I, o, m, l, t, r)

position

meter type

2

1 – 4, as applicable for group
see meter Type definitions

dIAG – Diagnostic Commands

this command is used to return status and diagnostic information. It is intended to be used as a text command only.
This is a query only command.

Command Form

: DEVICE dIAG [value]

Argument

Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

23 (J)

value

unsigned
short

2

0 = list of current commands
(J) power amp
1 = Fan/temp
2 = noise gate
3 = Feedback nodes

Information

string

80

Diagnostic string
(alWays null In text)