beautypg.com

ClearOne comm CONVERGE SR 1212 User Manual

Page 249

background image

244

GATE – Gate Status

this command reports the gate status of mics. This command is read only.

Command Form

: DEVICE GATE [value]

Argument

Type

Size

Values

units

value

hexadecimal

4

Bits 0 – 7 represent gate status on mics 1 – 8
(null sent in text, value returned)

GHOLd – Gate Hold Time Adjust

this command selects/reports the setting of hold time.

Command Form

: DEVICE GHOLd [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

3 (m)

value

unsigned Float

2

0.10 – 8.00
(null to query in text)

s

GmOdE – Gating Mode

this command selects/reports the setting of gating mode.

Command Form

: DEVICE GmOdE [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

3 (m)

value

unsigned Integer

2

1 = auto
2 = manual on
3 = manual off
(null to query in text)

GOVER – Gating Override

this command selects/reports the setting of gating override.

Command Form

: DEVICE GOVER [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

3 (m)

value

unsigned Integer

2

0 = off
1 = on
2 = toggle
(null to query in text)

GPIOSTATuS – General Purpose Status

this command sets the state of a general purpose status pin.

Command Form

: DEVICE GPIOSTATuS pin port [value]

Argument Type

Size

Values

units

pin

unsigned
Integer

1

1 – 24 (only user definable status pins.

port

unsigned
Integer

1

1 – 2

value

unsigned
Integer

2

0 = high
1 = low
2 = toggle
(null to query in text)

This manual is related to the following products: