ClearOne comm CONVERGE SR 1212 User Manual
Page 248
243
FILTSEL – Filter Select
this command turns on and off the filters.
Command Form
: DEVICE FILTSEL
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
3, 5 (m, p)
node
unsigned Integer
1
group 3
1 – 4
0xFF for all (*
text)
group 5
1 – 15
0xFF for all (*
text)
value
unsigned Integer
1
0 = off
1 = on
2 = toggle
(null to query in text)
FLOw – Flow Control
this command selects/reports the flow control of the serial port on the unit. hardware flow control is implemented
using Dtr and Dsr.
Command Form
: DEVICE FLOw [value]
Argument Type
Size
Values
units
value
unsigned Integer
4
0 = off
1 = on
2 = toggle
(null to query in text)
FmP – First Mic Priority Mode
this command selects/reports first mic priority mode.
Command Form
: DEVICE FmP
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
4 (g)
value
unsigned Integer
2
0 = off
1 = on
2 = toggle
(null to query in text)
GAIN – Gain Adjustment
this command changes or reports back the gain for a channel.
Command Form
: DEVICE GAIN
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
1, 2, 3, 5, 7, 12, 16, 17 (I, J, o, m, p, l, F, t, r)
value
signed
Float
2
-99.90 – 99.90 **
(null to query in text)
dB
absol / rel
0
a = absolute
r = relative
null = relative
NOTE: values indicate valid range for entry values only. actual internal range of the gain stage is
from –65 to 20. absolute values will be limited to the internal gain range.