ClearOne comm CONVERGE SR 1212 User Manual
Page 262
257
PAEqEN – PA EQ Filter Enable
this command enables the eq filter on a pa Channel
Command Form
: DEVICE PAEqEN
Argument Type
Size
Values
units
Channel
Channel
1
see groups and Channels
group
group
1
23 (J)
value
unsigned
short
2
0 = off
1 = on
2 = toggle
(null to query in text)
PAEqRST – PA EQ Filter Reset
this command resets the eq level for all bands in the filter bank. There is no query associated with this
command.
Command Form
: DEVICE PAEqEN
Argument
Type
Size
Values
units
Channel
Channel
1
see groups and Channels
group
group
1
23 (J)
reserved
Zero
2
Zero
PAEqSET – PA EQ Filter Set
this command sets/reports the eq level for a given band in the filter bank
Command Form
: DEVICE PAEqEN
Argument
Type
Size
Values
units
Channel
Channel
1
see groups and Channels
group
group
1
23 (J)
Band
unsigned
short
2
1 = 32.25 hz
2 = 62.5 hz
3 = 125.0 hz
4 = 250.0 hz
5 = 500.0 hz
6 = 1000.0 hz
7 = 2000.0 hz
8 = 4000.0 hz
9 = 8000.0 hz
10 = 16000.0 hz
hz
value
signed
Float
4
-12.00 – 12.00
(null to query in text)
dB