PAEqEN – PA EQ Filter Enable

this command enables the eq filter on a pa Channel

Command Form

: DEVICE PAEqEN [value]

Argument Type

Size

Values

units

Channel

Channel

1

see groups and Channels

group

group

1

23 (J)

value

unsigned
short

2

0 = off
1 = on
2 = toggle
(null to query in text)

PAEqRST – PA EQ Filter Reset

this command resets the eq level for all bands in the filter bank. There is no query associated with this
command.

Command Form

: DEVICE PAEqEN [value]

Argument

Type

Size

Values

units

Channel

Channel

1

see groups and Channels

group

group

1

23 (J)

reserved

Zero

2

Zero

PAEqSET – PA EQ Filter Set

this command sets/reports the eq level for a given band in the filter bank

Command Form

: DEVICE PAEqEN [value]

Argument

Type

Size

Values

units

Channel

Channel

1

see groups and Channels

group

group

1

23 (J)

Band

unsigned
short

2

1 = 32.25 hz
2 = 62.5 hz
3 = 125.0 hz
4 = 250.0 hz
5 = 500.0 hz
6 = 1000.0 hz
7 = 2000.0 hz
8 = 4000.0 hz
9 = 8000.0 hz
10 = 16000.0 hz

hz

value

signed
Float

4

-12.00 – 12.00
(null to query in text)

dB