ClearOne comm CONVERGE SR 1212 User Manual
Page 240
235
value
unsigned Integer
4
1 = master
2 = slave
(null to query in text)
dECAy – Decay Adjust
this command selects/reports the setting of the decay rate.
Command Form
: DEVICE dECAy
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
3 (m)
value
unsigned Integer
2
1 = slow
2 = medium
3 = Fast
(null to query in text)
dEFAuLT – Default The Unit
sets the unit to factory defaults. There is no query for this command.
Command Form
: DEVICE dEFAuLT
No Arguments
dELAy – Delay Adjust
this command selects/reports the setting of delay time.
Command Form
: DEVICE dELAy
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
5 (p)
value
unsigned Float
2
0.00 – 250.00
(null to query in text)
ms
dELAySEL – Delay Select
this command selects/reports the delay activation of an assignable processing channel.
Command Form
: DEVICE dELAySEL
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
5 (p)
value
unsigned Integer
2
0 = off
1 = on
2 = toggle
(null to query in text)
dEVICENAmE – Argument Identification Label
this selects/reports the Device argument identification label of the specific channel.
COMMAND FORM
: DEVICE dEVICENAmE
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
1, 2, 3, 7
(I, o, m, l)