PAFLT – PA Fault

this indicates one of the power amplifier channels is in a Fault condition. This is Read-Only, and is
automatically generated if a fault occurs.

Command Form

: DEVICE PAEqEN [Bitmap]

Argument Type

Size

Values

Bitmap

hexadecimal Integer 4

PAImPEd – PA Output Impedance

this command selects the output impedance for the pa channel to be either 8 ohms or 70/100v.

Command Form

: DEVICE PIAmPEd [value]

Argument

Type

Size

Values

units

Channel

Channel

1

see groups and Channels

group

group

1

23 (J)

value

unsigned
short

2

0 = 8 ohms
1 = 70/100v
(null to query in text)

PALEN – PA Limiter Enable

this command changes enables the limiter on a power amplifier channel.

Command Form

: DEVICE PALEN [value]

Argument Type

Size

Values

units

Channel

Channel

1

see groups and Channels

group

group

1

23 (J)

value

unsigned short

2

0 = off
1 = on
2 = toggle
(null to query in text)

PALT – PA Limiter Threshold

this command sets the limiter threshold on a power amplifier channel.

Command Form

: DEVICE PALT [value]

Argument Type

Size

Values

units

Channel

Channel

1

see groups and Channels

group

group

1

23 (J)

value

signed Float

2

-65.00 to +20.00
(null to query in text)

dB