ClearOne comm CONVERGE SR 1212 User Manual
Page 263
258
PAFLT – PA Fault
this indicates one of the power amplifier channels is in a Fault condition. This is Read-Only, and is
automatically generated if a fault occurs.
Command Form
: DEVICE PAEqEN [Bitmap]
Argument Type
Size
Values
Bitmap
hexadecimal Integer 4
PAImPEd – PA Output Impedance
this command selects the output impedance for the pa channel to be either 8 ohms or 70/100v.
Command Form
: DEVICE PIAmPEd
Argument
Type
Size
Values
units
Channel
Channel
1
see groups and Channels
group
group
1
23 (J)
value
unsigned
short
2
0 = 8 ohms
1 = 70/100v
(null to query in text)
PALEN – PA Limiter Enable
this command changes enables the limiter on a power amplifier channel.
Command Form
: DEVICE PALEN
Argument Type
Size
Values
units
Channel
Channel
1
see groups and Channels
group
group
1
23 (J)
value
unsigned short
2
0 = off
1 = on
2 = toggle
(null to query in text)
PALT – PA Limiter Threshold
this command sets the limiter threshold on a power amplifier channel.
Command Form
: DEVICE PALT
Argument Type
Size
Values
units
Channel
Channel
1
see groups and Channels
group
group
1
23 (J)
value
signed Float
2
-65.00 to +20.00
(null to query in text)
dB