ClearOne comm CONVERGE SR 1212 User Manual
Page 270
265
RINGEREN – Audible Ring Enable
this command sends/reports the use of an audible ring.
Command Form
: DEVICE RINGEREN
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
17 (r)
value
unsigned Integer
2
0 = off
1 = on
2 = toggle
(null to query in text)
RINGERLVL – Audible Ring Level
this command selects/reports the audible ring’s level.
Command Form
: DEVICE RINGERLVL
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
17 (r)
value
signed Float
2
-12.00 – 12.00 (dB)
(null to query in text)
RINGERSEL – Audible Ring Melody Selection
this command sends/reports the audible ring melody.
Command Form
: DEVICE RINGERSEL
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
17 (r)
value
unsigned Integer
2
1 – 3
(null to query in text)
RINGERTEST – Audible Ring Melody Test
this command plays the current audible ringer melody. This command is executable only. There is no query.
Command Form
: DEVICE RINGERTEST
Argument
Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
17 (r)
reserved
unsigned Integer
2
0
RINGmOd – Ring Cadence Mode
this command sets the ring cadence to either standard mode or custom mode. the cadence can be set using the
rIngon and rIngoFF commands. the country code should be set first using the Country command.
Command Form
: DEVICE RINGmOd
Argument
Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
17 (r)