GRATIO – Gate Ratio Adjust
this command selects/reports the setting of the gate ratio.
Command Form
: DEVICE GRATIO
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
3 (m)
value
unsigned Integer
2
0 – 50
(null to query in text)
dB
GREPORT – Gate Report
this command selects/reports the mode of gate and audio presence status reporting.
Command Form
: DEVICE GREPORT [value]
Argument Type
Size
Values
units
value
unsigned Integer
4
0 = off
1 = on
2 = toggle
(null to query in text)
GRPSEL – Gating Group Select
this command selects/reports which gating group a microphone input is assigned.
Command Form
: DEVICE GRPSEL
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
3 (m)
value
Channel
2
see 4 (g) in Groups and Channels
(null to query in text)
HOOk – Hook Flash
this command sends a hook flash. There is no query for this command.
Command Form
: DEVICE HOOk
Argument
Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
17 (r)
reserved
2
0
HOOkd – Hook Flash Duration
this command selects/reports the hook flash duration.
Command Form
: DEVICE HOOkd
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
17 (r)
value
unsigned Integer
2
50 – 2000
(multiples of 10 ms only)
(null to query in text)
ms