ClearOne comm CONVERGE SR 1212 User Manual
Page 239
234
COmPRESS – Compressor Adjust
this command selects/reports the settings of the compressor.
Command Form
: DEVICE COmPRESS
Argument
Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
5 (p)
threshold
signed Integer
1
-60 – 20
(null to query in text)
dB
ratio
unsigned Integer
1
1 – 20
attack
unsigned Float
2
0.00 – 100.00
ms
release
unsigned Integer
2
100 – 2000
ms
gain
unsigned Float
4
0.00 – 20.00
dB
COmPSEL – Compression Select
this command selects/reports the compressor activation.
Command Form
: DEVICE COmPSEL
Argument Type
Size
Values
units
Channel
Channel
1
see Groups and Channels
group
group
1
5 (p)
value
unsigned Integer
2
0 = off
1 = on
2 = toggle
(null to query in text)
COuNTRy – Country Selection
this command sets / reports the country for telco compliance purposes.
Command Form
: DEVICE COuNTRy [value]
Argument Type
Size
Values
units
value
unsigned Integer
4
1 = us / Canada
2 = europe
3 = mexico
4 = australia
5 = south africa
6 = Japan
7 = Brazil
8 = south Korea
9 = China
10 = singapore
11 = taiwan
12 = new Zealand
13 = India
14 = hong Kong
15 = malaysia
16 = argentina
(null to query in text)
CTRLmASTER – Control Master Mode
this command reports the mode of the unit for snmp control.
Command Form
: DEVICE CTRLmASTER [value]
Argument Type
Size
Values
units