75
ranges from 0 to 20ms.
Note: groups do not interact with processor channels.
mute
•
: mutes the specific power amp channel.
Polarity
•
: reverses the amplifier’s output polarity.
Eq Filter
•
: adjusts specific frequency bands within a +/-12db range.
Enable Eq Filter
»
: enables or disables the eq.
Limiter
•
: establishes a ceiling level for the amplifier output.
Enable Limiter
»
: limits the output to the Threshold/max level specified by the user.
Enable Soft Clipper
»
: softens the clipping effect at Threshold/max level to prevent damage to
external equipment.
Note: Both settings can be active simultaneously.