beautypg.com

ClearOne comm CONVERGE SR 1212 User Manual

Page 259

background image

254

mTRxLVL – Matrix Attenuation Adjust

this command selects/reports the matrix level at the cross point.

Command Form

:

DEVICE mTRxLVL [value] [a/r]

Argument

Type

Size

Values

units

source Channel

Channel

1

see Groups and Channels

source group

group

1

1, 3, 5, 6, 7, 12, 17
(I, m, p, e, l, F, r)

Destination Channel

Channel

1

see Groups and Channels

Destination group

group

1

2, 5, 6, 12, 16,
(h, J, o, p, e, F, t,)

value

signed Float

4

-99.00 – 99.00 **
(null to query in text)

dB

absol / rel

0

a = absolute
r = relative
null = relative

NOTE: values indicate entry range only. actual internal range of the matrix attenuation is from –60

to +12dB, and absolute values are limited to the internal gain range.

muTE – Mute

this command selects/reports the setting of mute on a channel.

Command Form

: DEVICE muTE [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

1, 2, 3, 5, 7, 12, 16, 17 (I, J, o, m, p, l, F, t, r)

value

unsigned Integer

2

0 = off
1 = on
2 = toggle
(null to query in text)

NAmE – Unit Name (NETBIOS Name)

this command sets/reports the name of the unit which is also used for its netBIos name.

Command Form

: DEVICE NAmE [value]

Argument Type

Size

Values

units

value

string

16

1 – 15 Characters
(null to query in text)

NCd – Noise Cancellation Depth Adjust

this command selects/reports the depth setting of the noise Cancellation.

Command Form

: DEVICE NCd [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

3, 17 (m, r)

value

unsigned Integer

2

6 – 15
(null to query in text)

dB