beautypg.com

ClearOne comm CONVERGE SR 1212 User Manual

Page 275

background image

270

SySCHECkS – System Checks

Initiates the system checks. There is no query for this command.

the System Check integer bits determine which tests are run. each bit set generates a separate sysresult
response.

COMMAND FORM

:

DEVICE SySCHECkS

Argument Type

Size Values

system
Check

hexadecimal
Integer

4

15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00

network

telephone

mic 1

mic 2

mic 3

mic 4

mic 5

mic 6

mic 7

mic 8

all other bits reserved

SySRESuLT – System Check Result

this command reports the results of the system check. This command is reportable only. It cannot be
queried or set.
the System Check integer bits determine which test result will be reported. each test results in
a separate sysresult message.

Argument Type

Size

Values

system
Check

hexadecimal
Integer

4

15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00

network

telephone

mic 1

mic 2

mic 3

mic 4

mic 5

mic 6

mic 7

mic 8

all other bits reserved

status

unsigned
Integer

2

0 = Fail
1 = pass
2 = null

packet loss statistics

sIp proxy registration status

power amp Fault Check

power amp temp Check

packet loss statistics

sIp proxy registration status

power amp Fault Check

power amp temp Check