ClearOne comm CONVERGE SR 1212 User Manual
Page 275
270
SySCHECkS – System Checks
Initiates the system checks. There is no query for this command.
the System Check integer bits determine which tests are run. each bit set generates a separate sysresult
response.
COMMAND FORM
:
DEVICE SySCHECkS
Argument Type
Size Values
system
Check
hexadecimal
Integer
4
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
network
telephone
mic 1
mic 2
mic 3
mic 4
mic 5
mic 6
mic 7
mic 8
all other bits reserved
SySRESuLT – System Check Result
this command reports the results of the system check. This command is reportable only. It cannot be
queried or set. the System Check integer bits determine which test result will be reported. each test results in
a separate sysresult message.
Argument Type
Size
Values
system
Check
hexadecimal
Integer
4
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
network
telephone
mic 1
mic 2
mic 3
mic 4
mic 5
mic 6
mic 7
mic 8
all other bits reserved
status
unsigned
Integer
2
0 = Fail
1 = pass
2 = null
packet loss statistics
sIp proxy registration status
power amp Fault Check
power amp temp Check
packet loss statistics
sIp proxy registration status
power amp Fault Check