Appendix b: default pinouts – ClearOne comm CONVERGE SR 1212 User Manual
Page 285
280
appenDIx B: DeFault pInouts
CONTROL/STATuS PORTS
Converge Pro 880: Port A (Female dB-25)
pin #
user Definable
Control/status
Default Description
1
y
Control (Input)
2
y
status (output)
3
y
Control (Input)
mute all mics toggle
4
y
status (output)
status of mute all mics
5
y
Control (Input)
mute output 9 toggle
6
y
status (output)
status of mute output 9
7
y
Control (Input)
mute output 10 toggle
8
y
status (output)
status of mute output 10
9
y
Control (Input)
mute output 11 toggle
10
y
status (output)
status of mute output 11
11
y
Control (Input)
mute output 12 toggle
12
y
status (output)
status of mute output 12
13
y
Control (Input)
volume up output 1 (1 dB)
14
y
status (output)
15
y
Control (Input)
volume Down output 1 (1 dB)
16
y
status (output)
17
n
status (output)
microphone 1 gate status
18
n
status (output)
microphone 2 gate status
19
n
status (output)
microphone 3 gate status
20
n
status (output)
microphone 4 gate status
21
n
status (output)
microphone 5 gate status
22
n
status (output)
microphone 6 gate status
23
n
status (output)
microphone 7 gate status
24
n
status (output)
microphone 8 gate status
25
na
na
ground