Overview
22000
Overview
Overview
2-
Uebersicht_Allgemein
The PSENvip is a camera-based protection and measuring system
(electrosensitive protective equipment) for press brakes. It consists of a
transmitter and receiver. The PSENvip monitors the detection zone be-
tween the transmitter and receiver below the moving upper tool.
Uebersicht_Merkmale_Sender
Transmitter
Generates parallel beam
2 inputs for controlling the light source
Uebersicht_Merkmale_Empfaenger
Receiver
Evaluates the light generated by the transmitter
Display for the operating statuses and inputs
Membrane keypad for operating the menus and for inputs
Max. distance between transmitter and receiver: 10 m
Uebersicht_Merkmale_Empfaenger_Eingaenge
Inputs
1 input for setup mode
1 input for signalling when the press brake is at top dead centre
2 inputs for controlling the protected field mode:
Protected field can be adapted to a range of bending functions: full
protected field, reduced protected field for box bending and lower
tools with back gauge
1 input for acknowledging the protected field mode
Uebersicht_Merkmale_Empfaenger_Ausgaenge
Outputs
2 output signal switching devices (OSSD) for signalling the status of
the protected field (clear or interrupted)
Uebersicht_Merkmale_Empfaenger_Ausgaenge_Mute
2 outputs for signalling that PSENvip is in dynamic muting
Uebersicht_Merkmale_Empfaenger_Ein_Aus_Zusatz
Some inputs and outputs are used for communication with the safety
system during the system status TEST:
Register tool class on safety system
Approve tool class for PSENvip
Uebersicht_Merkmale_Empfaenger_LED
LED indicators for
Status of OSSDs
Uebersicht_Merkmale_Betriebszustaende
Operating statuses
Adjustment for initial commissioning
Tool change
Diagnostics
Uebersicht_Merkmale_Werkzeugerkennung