Enter overrun

7

Commissioning

7.4

Enter overrun

7400

Enter overrun

7-

Inbetriebnahme_Nachlaufweg_eingeben_P_Variante_1

The max. overrun is a press brake variable that will depend on the ma-
chine type. Once the closing movement has stopped, the max. overrun
must not be exceeded.

The overrun is entered during configuration via the keypad on the PSEN-
vip receiver.

Funktion_Nachlaufweg_P_Variante

Normally, the factory-assigned overrun is sufficient and does not have
to be configured.

Funktion_Nachlaufweg_Warnung_3

Inbetriebnahme_Nachlaufweg_eingeben_P_Variante_2

To enter the overrun, follow the instructions below:

Switch off the voltage to the PSENvip.

Press the + keys and keep them held down.

Switch the supply voltage back on.

Release the + keys when Password? appears on
the display.

Enter the password within 10 s.

To do this, press the following keys in the specified sequence: 1.

,

2.

, 3. , 4. .

The menu for entering the overrun will appear.

NOTICE
The overrun may only be entered by the press brake manufac-
turer or suitably authorised persons.

WARNING!
If you require a different overrun path than the factory-set path,
then use the value indicated by the manufacturer on the name-
plate of the press brake, or a higher value.
If you enter a lower value for the overrun, the protected field will
also be reduced to an unpermitted level.
Failure to comply

could result in a hazardous situation, which

could lead to serious injury and death.