7 show startupconfig, 8 startupslot config, 9 startupslot activate – Kontron AT890X Full-Size CLI User Manual
Page 202: 3 atca commands, 1 set board sensor threshold, Show startupconfig - 4, Startupslot config - 4, Startupslot activate - 4, 3 atca commands - 4, Set board sensor threshold - 4
Utility Commands
AT8901/2/3
AT8901/2/3 CLI Reference Manual
Page 5 - 4
Format
download bootloader
Mode
Privileged EXECEXEC
5.2.7
show startupconfig
This command shows the slots for kernel/initrd/application/config or all possible
configured combinations of the above
Format
show startupconfig {application | kernel | initrd | star-
tup | config | all}
Mode
Privileged EXEC
5.2.8
startupslot
This command configures the startup slot with the supplied values from the other slots.
It will also check the configuration for consistency and flag any errors.
Format
startupslot
Mode
Global Config
5.2.9
startupslot
This command sets the startup slot to active and will use this in all subsequent reboots.
Using [once] at the end of the command will set the startup slot to be used once during
the next restart. The start sequence will reset the startup slot to the previously installed
one. This enables a try-once with automatic rollback in case of error.
Format
startupslot
Mode
Global Config
5.3
ATCA commands
5.3.1
set board sensor threshold
This command sets a new threashold value for a sensor. The
a specific sensor is displayed by the related “show” command
Format
set board sensor threshold
Mode
Privileged EXEC
•
lower-non-critical
Set lower non-critical threshold value
•
lower-critical
Set lower critical threshold value
•
lower-non-recover
Set lower non-recoverable threshold value
•
upper-non-critical
Set upper non-critical threshold value
•
upper-critical
Set upper critical threshold value
•
upper-non-recover
Set upper non-recoverable threshold value