background image

h2000 User Manual

88

HB-0845-06

8. Press

Enter to store the new value into the

system.

9.

Press

Page to return to full display.

3.2.7

Speed Calibration Referenced to a Known

Value

To calibrate the Boat Speed by reference to a known value,
e.g. another boat with an accurately calibrated log, proceed
as follows:

1. Select BOAT SPD KT on upper half of FFD

display:

2. Press

Scroll Down until the lower text shows

CALBRATE flashing.

3. Press

Enter, the lower text now shows AUTO

CAL flashing.

4. Press

Scroll Down until the lower text shows

REF CAL flashing.

5. Press

Enter, the lower text now shows REF CAL

along with the current value of Boat Speed.

6. Press

Enter, the lower text now shows the REF

CAL value flashing and by use of the Scroll
Up/Down
the reference speed may be adjusted to
the new value.

7. Press

Enter, the new speed value is accepted and

the upper display will show the re-calibrated Boat
Speed.

3.2.8

Boat Speed Units (Knots, MPH, KPH)

To configure the required boat speed units proceed as
follows:

1. Press

Scroll Up until the upper text shows LOG

flashing.