B&G H2000 Pilot *DISCONTINUED* User Manual
Page 194
h2000 User Manual
194
HB-0845-06
5.15.31 h2000 General Purpose Input Value
####
IV,nnn,mmm,fff,xx.xx,tttttttttt(CR)
nnn = node number to which value is to be sent
1
- Depth
Board
5 to 8 - Wind Boards
9 to 12 - RS232 or NMEA Board
255 - Broadcast to all Boards
mmm = message type to be used
211
- Calibration
Value
1
212
- Calibration
Value
2
213
- Calibration
Value
3
214
- Calibration
Value
4
206
- Damping
Value
34
- High
Alarm
Value
33
- Low
Alarm
Value
32
- Sector
Alarm
Value
1
- Data
Value
2 - New text for an existing function
fff = function number see Table 14
xx.xx = Value value to be sent, or node number of function
fff if mmm=2
tttttttttt = function text displayed on FFD, 20/20 or 40/40
This is a general purpose command for inputting values to
other nodes.
5.15.32 General Purpose Output Value
####
OV,nnn,mmm,fff,(CR)