B&G H2000 Pilot *DISCONTINUED* User Manual
Page 175
HB-0845-06
175
5.15.5 Automatic Output Enable/Disable
####
OE,nn,s,h(CR)
nn = 00 to 31 channel number
s = 0 for automatic output of channel disabled
s = 1 for automatic output of channel enabled
h = H indicates reference to Hercules channel
h = R indicates reference to NMEA or Remote channel.
The data output rate depends on the channel number, as
shown in Table 7.
5.15.6 Automatic Output Start/Stop
####
OS,s(CR)
s = 0 to stop all RS232 automatic output.
s = 1 to start all RS232 automatic output which has been
enabled.
When an automatic start command is executed, all Hercules
and remote channels that have been enabled using the
####
OE
command will be output regularly.
Data for Hercules functions is output as follows:-
nn,x...x(CR)
nn = channel number (00 to 31).
x...x = ASCII data.
Data for NMEA or Remote channels is output as follows:-
rnn,x...x(CR)
nn = Remote channel number (00 to 31).
x...x = ASCII data.
Examples: