CAL VAL 2
Setting
Function Text Shown
0 AFT
DPTH
1 FWD
DPTH
2 MID
DPTH
3 PORT
DEP
4 STBD
DEP
5 DEPTH
2
3.9 BATTERY
VOLTS
The h2000 monitors the yacht's battery supply and can be
shown on any display, giving a reading in volts. This is
calibrated by the manufacturer and should not require
adjustment except in exceptional circumstances or after a
system reset. If it is necessary to calibrate this function a
suitable voltmeter is required. The calibration value is found
in the menu under:
MOTOR
→
VOLTS, CALBRATE
→
CAL VAL1
Using the independent voltmeter, measure the battery
supply at terminals 18 (+) and 17 (-) at the Computer Unit
connection block.
Alter CAL VAL1 to match the value from the voltmeter.
3.10 SEA
TEMPERATURE
If a suitable temperature sensor is fitted, the h2000 will
monitor the current sea temperature.
The paddle-wheel has a sensor incorporated within it, in this
case no further action is required.
If the sensor is a totally independent fitting (B&G part no.
224-00-065) then it is necessary to change the sensor
selection value.
This value is found in: