B&G H2000 Pilot *DISCONTINUED* User Manual
Page 37
HB-0845-06
37
8.
Press
Page to return to normal display.
Damping control for any of the other functions that can be
damped is completed in a similar manner.
2.4
EXAMPLES OF CALIBRATION
The method of calibration for your h2000 System should be
made clear by following the examples of calibration. The
calibration process is described in detail in Chapter 3 -
Calibration.
2.4.1 Manual Calibration Adjustment - Boat Speed
1.
Select BOAT SPD.
2. If BOAT SPD is in the upper display, press and
hold the Scroll Down Key to select CALIBRATE
from the menu.
3.
Press
Enter then press Scroll Down and the
display shows MANL CAL, which is the choice
that we require.
4.
Press
Enter and the display shows SINGLE.
Notes
SINGLE is the choice required if a single speed sensor is
fitted.
If two paddle-wheels are fitted, the Scroll Up or Scroll
Down Keys should be used to select PORT CAL or STBD
CAL, as required.
5.
Press
Enter to reveal the current calibration value
in Hertz/knot.
6. To adjust the calibration value, press Enter and
the value flashes.
7. Use
Scroll Up or Scroll Down to change the
calibration value as required to the new
calibration value.