beautypg.com

B&G H2000 Pilot *DISCONTINUED* User Manual

Page 192

background image

h2000 User Manual

192

HB-0845-06

D,n,xx(CR)
xx = damping value 0 to 99

5.15.28 Input Hercules Channel Text

####

IT,nn,c...c,d...d(CR)

nn = 00 to 31 - Hercules Channel Number (see Table 7)
c...c = channel text, up to 16 characters (only 10 displayed)
d...d = Page Text, ignored by h2000.

5.15.29 Output Text Immediately

####

OT,nn,h(CR)

nn = 00 to 31 channel number
h = H for Hercules channel (see Tables 7 and 8)
R for NMEA or Remote channel.

Note

Remote channel numbers must be allocated by adjusting

CAL VAL3 for the required function or using the

####

RC,nn,cc(CR) command.

This command stops all automatic output and outputs text as
follows (page text is returned as spaces)

HT,nn,c...c, (CR) if Hercules channel text requested
RT,nn,c...c, (CR) if Remote Text requested.

5.15.30 Output Alarm

####

OA,nn(CR)

nn = alarm number, see Table 13

This command stops all automatic output, and returns

Ann,xxxx,s(CR)
nn = Alarm Number
xxxx = Alarm Value
s = 0 for alarm OFF
s = 1 for alarm ON and not active
s = 3 for alarm ON and active