beautypg.com

B&G H2000 Pilot *DISCONTINUED* User Manual

Page 144

background image

h2000 User Manual

144

HB-0845-06

Enter will select that option, and the meter drive
will be configured to drive a DEPTH meter.

6. Press

Page to return to normal operation.

Note

It is possible to configure more than one meter drive to the
same meter option (e.g. BOAT SPD on METER 1 and
METER 2).

5.3.4 Meter

Scaling

Meter scaling can also be varied for boat speed and wind
speed. For example, if a 25 knot full scale Boatspeed Meter
is required, this can be done as follows:

1.

Follow steps (1) and (2) as detailed in Para 5.3.3.

2. With OPTIONS flashing, press Scroll Up to

reveal SCALING, press Enter, BOAT SPD will
appear. A further press of Enter will reveal the
current maximum meter scale value for the
Boatspeed Meter.

3.

To change this (e.g. to 25 knots) press Enter and
then Scroll Up to increase the number to 25.0. A
final press of Enter will then enter the new
maximum scale. The Boatspeed Meter will read
between 0 and 25 knots.

4. Press

Page to return to normal operation.