beautypg.com

B&G H2000 Pilot *DISCONTINUED* User Manual

Page 85

background image

HB-0845-06

85

Cal Dist

X

Start Run 1

"Enter"

Stop Run 2

"Enter"

"Scroll Up"

or

"Scroll Down"

Start Run 3

"Enter"

Stop Run 1

"Enter"

Start Run 2

"Enter"

"Scroll Up"

or

"Scroll Down"

End Cal

"Enter"

A

B

Figure 8 - Calibration Runs

The user is required to enter the distance X in nautical miles
(CAL DIST) and then, as the yacht passes marks A and B
on each run, to instruct the system to start (STRT RUN) and
stop (STOP RUN) and finally to end calibration (END
CAL) after the last run is completed.

Note

The calibration process can be cancelled at any time during
the operation by pressing the Page Key, if the operator is
not satisfied with the calibration runs underway, e.g.,
hampered by another vessel, or wash etc.

3.2.5

Log AUTO CAL Procedure

1.

Select BOAT SPD on the upper display.

2.

Press and hold Scroll Down to select
CALBRATE.