H2000 user manual, Button ffd installation – B&G H2000 Pilot *DISCONTINUED* User Manual
Page 122
h2000 User Manual
122
HB-0845-06
8-Button FFD Installation
Junction Box
288-00-001
Connect like
wires together
Fastnet Cable
135-0A-130
FFD Cable
Function
FFD Cable
Colour
System
Network
Network Data -ve
Green
Green
Network Data +ve
White
White
Network Cable Shield
Shield
Shield
Ground Black
Black
Supply +ve
Red
Red
Not used
Yellow
Not used
Brown
FFD Installation Notes
•
The system requires at least one FFD.
•
An FFD can be connected at any point on the system network.
•
Multiple FFDs can be used on the system network. Each can control and enter data into the
system processor memory.
•
FFDs can be used in combination with all other display types i.e. NMEA FFDs, Halcyon
displays, 20/20 and Pilot displays.
•
To prevent water intrusion into the display, do not cut the cable shorter than marked by the
yellow band. If it is necessary to cut cables, then the wires MUST be tinned with a soldering iron
to ensure a proper seal around the wires.
•
Screened Cables
o
Shielded cables are supplied to provide protection against unwanted emissions (EMC)
and must be connected in accordance with these instructions.
•
Network Termination
o
If the FFD is the last unit on the system network a network terminator MUST be fitted
across the network data wires, i.e. between the green and white wires.