HB-0845-06

205

set to the same function as any one of the Linear 5 to 16
inputs.

Calibration value 2 (CAL VAL 2) displays MIN VAL with
a number that can be adjusted between -999 and 9999. This
is the number to be displayed for a 0V input. The default
setting is 0.

Calibration value 3 (CAL VAL 3) displays MAX VAL with
a number that can be adjusted between -999 and 9999. This
is the number to be displayed for 6.5V input. The default
setting is 1000.

5.16.3 Calibrating a Linear Channel

Adjusting the MIN and MAX values allows the displayed
value to be scaled to the appropriate range for the sensor
attached. Taking a load cell for example, if the zero load
output is 0V, MIN VAL=000 and if maximum load is 650
KgF at 6.5V then MAX VAL=650.

Calibration value 4 is only available on Linear 5 and this
displays a value between 05 and 16. This setting determines
the number of linear inputs that are available. For example,
changing this value to 10 would display a maximum of 10
linear inputs. The default value is 05.

Damping is adjustable between 00 and 99 seconds. The
default setting is 01.

Notes

When calibration value 1 is changed to select a desired

input sensor, the linear value is no longer updated and a
constant value is displayed until the page key is pressed.

Extra functions selected, and then removed, remain in

the display menu but with no data shown until the system
is switched off and then back on again.