set to the same function as any one of the Linear 5 to 16
inputs.
Calibration value 2 (CAL VAL 2) displays MIN VAL with
a number that can be adjusted between -999 and 9999. This
is the number to be displayed for a 0V input. The default
setting is 0.
Calibration value 3 (CAL VAL 3) displays MAX VAL with
a number that can be adjusted between -999 and 9999. This
is the number to be displayed for 6.5V input. The default
setting is 1000.
5.16.3 Calibrating a Linear Channel
Adjusting the MIN and MAX values allows the displayed
value to be scaled to the appropriate range for the sensor
attached. Taking a load cell for example, if the zero load
output is 0V, MIN VAL=000 and if maximum load is 650
KgF at 6.5V then MAX VAL=650.
Calibration value 4 is only available on Linear 5 and this
displays a value between 05 and 16. This setting determines
the number of linear inputs that are available. For example,
changing this value to 10 would display a maximum of 10
linear inputs. The default value is 05.
Damping is adjustable between 00 and 99 seconds. The
default setting is 01.
Notes
•
When calibration value 1 is changed to select a desired
input sensor, the linear value is no longer updated and a
constant value is displayed until the page key is pressed.
•
Extra functions selected, and then removed, remain in
the display menu but with no data shown until the system
is switched off and then back on again.