s = 0 for automatic output disabled
s = 1 for automatic output enabled at 2Hz
s = 2 for automatic output enabled at 4Hz

Sets or resets automatic output flag for basic raw data.
Automatic output is started using the

#

OS,1(CR) command.

Basic data is then output every half second as follows:

B,w...w,x...x,y...y,z...z(CR)
www.w = Boatspeed in Hz uncalibrated, 5 characters
xxx.x = Apparent Windspeed in Hz uncalibrated, 5
characters.
yyy.y = Apparent Wind Angle in degrees no offset, 5
characters
zzz.z = Heading in degrees after application of offset, 5
characters

If #OS,2(CR) is used basic data will be output every quarter
of a second.

5.15.9 Immediate Output of Basic Data

####

OB(CR)

This command stops all automatic output of other data and
outputs basic data immediately. Data is output using the
same format as automatic output of basic data.

Note

After automatic data has been stopped by this command

it can be restarted using the

####

OS,1(CR) command.

5.15.10 Immediate Output of Channel or Remote
Data

####

OI,nn,s(CR)