B&G H2000 Pilot *DISCONTINUED* User Manual
Page 177
HB-0845-06
177
s = 0 for automatic output disabled
s = 1 for automatic output enabled at 2Hz
s = 2 for automatic output enabled at 4Hz
Sets or resets automatic output flag for basic raw data.
Automatic output is started using the
#
OS,1(CR) command.
Basic data is then output every half second as follows:
B,w...w,x...x,y...y,z...z(CR)
www.w = Boatspeed in Hz uncalibrated, 5 characters
xxx.x = Apparent Windspeed in Hz uncalibrated, 5
characters.
yyy.y = Apparent Wind Angle in degrees no offset, 5
characters
zzz.z = Heading in degrees after application of offset, 5
characters
If #OS,2(CR) is used basic data will be output every quarter
of a second.
5.15.9 Immediate Output of Basic Data
####
OB(CR)
This command stops all automatic output of other data and
outputs basic data immediately. Data is output using the
same format as automatic output of basic data.
Note
•
After automatic data has been stopped by this command
it can be restarted using the
####
OS,1(CR) command.
5.15.10 Immediate Output of Channel or Remote
Data
####
OI,nn,s(CR)