B&G H2000 Pilot *DISCONTINUED* User Manual
Page 206
h2000 User Manual
206
HB-0845-06
•
Linear functions will always be shown if selected by
CAL VAL 4 on linear 5. They will show no data if the
CAL VAL 1 is set to 1 or 2.
5.16.4 Expansion Processor Wiring
The Expansion Processor is connected to the system Fastnet
for power and data requirements.
TERMINAL FUNCTION
WIRE
COLOUR
1 Meter
5
SIN
Green
2 Meter
5
COS
Blue
3 Meter
6
SIN
Red
4 Meter
6
COS
Violet
5 Meter
7
SIN
Red
6 Meter
7
COS
Violet
7 Meter
8
SIN
Green
8 Meter
8
COS
Blue
9 Meter
Lighting
Yellow
10 Meter
Common
Orange
11 Meter
Ground
Black
12 N/C
13 N/C
14 Network
Data
-ve
Green
15 Network
Data
+ve
White
16 Network
Screen
Screen
17 Battery
Supply
Ground Black
18 Battery
Supply
12V
Red
19
Battery Volts Sense
Link to 18
20 N/C
21 Ground
Blue
22 Sensor
Supply
+6.5V
Red
23
Linear 5 Input
Green
24
Linear 6 Input
Green
25
Linear 7 Input
Green
26
Linear 8 Input
Green
27
Linear 9 Input
Green
28 N/C