B&G H2000 Pilot *DISCONTINUED* User Manual
Page 87
HB-0845-06
87
Note
•
“Err” is displayed if the system encountered a problem
during the calibration run. For example, if the calibration
run distance was too short.
The log is now calibrated and the new calibration value is
stored permanently in the Main Processor memory.
3.2.6
Manual Calibration
The calibration values can be adjusted directly as follows:
1.
Select BOAT SPD in the upper display.
2. Press and hold the Scroll Down Key to select
CALIBRATE from the menu.
3. Press
Enter then press Scroll Down and the
display shows MANL CAL, which is the choice
that we require.
4. Press
Enter and the display shows SINGLE.
Notes
•
SINGLE is the choice required if a single paddle-wheel
or sonic speed is fitted.
•
If two paddle-wheels are fitted it is possible to access the
individual port and starboard calibration values: use the
Scroll Up or Scroll Down keys to select PORT CAL or
STBD CAL, as required. The Port and Starboard
calibration values refer to the sensor, i.e. port calibration
= port sensor (not “port tack”).
5. Press
Enter to reveal the current calibration value
in Hertz/knot.
6. To adjust the calibration value, press Enter and
the value flashes.
7. Use
Scroll Up or Scroll Down to change the
calibration value as required to the new
calibration value.