Multiple linear sensor inputs installation sheet – B&G H2000 Pilot *DISCONTINUED* User Manual
Page 131
HB-0845-06
131
Green
(G)
Terminal
Function
Wire Colour
21
22
23
24
25
26
27
Sensor ground
Sensor Supply 6.5V DC
Air temp. input
Heel sensor input
Trim sensor input
Baro. sensor input
Lin. 4 sensor (spare)
Blue
(B)
Red
(R)
Green
38
41
Baro./Compass ground
Baro./Compass supply
Blue
Red
MULTIPLE LINEAR SENSOR INPUTS
INSTALLATION SHEET
41
38
27
26
25
24
23
22
21
20
Black
Orange
Violet
R
G
R
G
R
G
R
G
B
Bn
B
B
B
B
R
B
G
Blk
O
Y
V
B
R
B
R
R
B
B
Air Temp. Sensor
224-00-060
Linear 4
(spare)
SatNav output
Heel
Trim
Clinometers
690-00-004
Barometric Pressure Sensor
690-00-007
18 Way Junction box
386-00-023
7-core cable
20
SatNav ouput
Yellow (Y)
Cable
Use 7-core
from processor
to junction box
Sensors have
cable attached
(Blk)
(O)
(V)
MAIN PROCESSOR
TERMINALS
Notes
1. Inter-connect all sensor supply (Red wires) and sensor ground (blue wires) in the junction box. For
clarity, these connections have been omitted from this diagram.
2. Rotary Mast Sensor (RRF-ACP) connections: Red=21; Blue=22, Green=27