B&G H2000 Pilot *DISCONTINUED* User Manual
Page 141
HB-0845-06
141
5.2.9 Sensor Input Configuration
Additional sensors can be added to the system connecting to
one of the four linear inputs on the main processor. Linear
channels 5 to 16 are available with the addition of an
Expansion Processor. These can be configured to take
different sensors. If you connect the sensor to the linear
input that B&G have anticipated then you need take no
action beyond the connection itself, since the default linear
input configuration will be the right one. The default
settings for the four inputs are as follows:
Linear 1 = Heel Angle (4)
Linear 2 = Trim Angle (5)
Linear 3 = Barometric Pressure (6)
Linear 4 = 0 to 1000 format (1)
Should you wish to connect one of the other sensors, then
you will have to reconfigure the input linear channel that
you are connecting it to. This is done by following the menu
path:
MISC
→
→
→
→
LINEAR X, CALBRATE
→
→
→
→
CAL VAL1
The number you enter to CAL VAL1 should correspond to
the sensor you are connecting as follows:
-2 = Normal Linear output to 2 decimal places
-1 = Normal Linear output to 1 decimal place
0 = Normal Linear output 0-1000
1 = Normal Linear output 0-1000
2 = Normal Linear output 0-1000
3 = Rotating Mast Correction (output Mast Angle
and Wind Angle to Mast)
4 =
Heel
Angle
5 =
Trim
Angle
6 = Barometric Pressure and Pressure Trend
7 =
Rudder