CAL
Alternating with a function value indicates
that it has yet to be calibrated. This will
happen after a system reset or if the internal
battery is exhausted.
NO SPACE FFD memory full, too many functions have
been declared.
NOT FND New function declared without text, can occur
temporarily at start-up or after changing a
system setting (e.g. True/Magnetic reference).
6.6
HALCYON 2000 COMPASS
6.6.1 Shows Heading and CAL Flashing
Symptom: Display flashes a Heading and CAL
Possible Causes:
a.
The memory in the Halcyon 2000 is empty or has
been corrupted. This may be due to a System
Reset being performed or the first time the
compass has been installed and not yet been
calibrated. Perform a calibration swing to restore
normal operation.
b. After a calibration swing the result is always
FAIL. There is a source of magnetic deviation
near to the Halcyon 2000 compass. Try re-
positioning the compass and perform the
calibration.
6.6.2 Heading Shows Err
Possible Causes:
a.
The signal from the fluxgate sensor is too big or
too small. Try re-positioning the compass. If still
showing Err set NAVIGATE
→
COMP CAL,
CALBRATE
→
→
→
→
CAL VAL 2 (RES CAL) to 1.