B&G H2000 Pilot *DISCONTINUED* User Manual
Page 218
h2000 User Manual
218
HB-0845-06
This will reset the compass. All previous
calibrations will be lost.
6.6.3 Heading or COMP CAL Shows PHS
Possible Causes:
a. The compass is in the middle of resetting, the
display should show heading and CAL flashing
after 20 seconds. A calibration swing will be
required.
6.6.4 Two Headings Flashing Alternately
Symptom: Pilot or Halcyon Displays shows 2 headings
flashing alternately
Possible Causes:
a. The Pilot has not been set to use the Halcyon
2000 as its heading source. See using Halcyon
2000 with a B&G ACP Pilot. If the Halcyon 2000
is not to be the source of heading then it must be
unplugged from the system.
6.6.5 True Wind Direction, Tide Set or DR Course
Not Functioning Correctly
a. The Main Processor has not been configured to
use the Halcyon 2000 as the main heading source.
Set the following to 16:
NAVIGATE
→
COURSE, CALBRATE
→
→
→
→
CAL VAL 1 (HDG NODE)